Solutions
Solutions | Synchronizing Systems
Beckwith Electric’s Synchronizing Systems are suitable for the automatic synchronizing of a generator to the electric power network. The system provides speed and voltage “jogs” to bring a generator to proper conditions of matching voltage and frequency, prior to safely and accurately closing a breaker into a bus energized by an electric power network. They offer the best accuracy in the industry to assure safety for your most expensive asset.
- Facilitates standardization for generator and system intertie sync check applications
- Assure safe and accurate connection of a generator to the power network
- Provides accuracy and independent controls; no additional instrumentation is required for field setting
- Breaker closing times are field programmable
- Local and remote serial communications (MODBUS protocol) capability for monitoring and control functions
Integrated Synchronizing System® for Generator and Intertie Synchronizing
- Unit can be multiplexed to different generators that have different breaker closing times.
- An infinite amount of different breaker closing times can be obtained by simple contact closures to the relay.
- Accurate, independent controls require no additional instrumentation for field setting
- Various ∆V and ∆F limits available
- Breaker closing times are field programmable
- 50 Hz operation available
- Matches Generator Speed And Voltage To System
- Works In Conjunction With M‑0193B Syncrocloser® Unit To Close Breaker At Zero Degrees Phase Angle Error
- Adjustable Jog Durations, proportional to error, for Voltage and Speed control.
- Time Between Jogs adjustments bring the generator to a matched condition in minimum time and eliminate overshoot and hunting.
- Kicker Pulse brings phase angle around through zero if speed is matched but synchronism has not yet occurred. Adjustable pulse duration compensates for the sensitivity of the governor.
- Accurate, independent controls require no additional instrumentation for field setting
- Voltage limit ranges and dead line/dead bus closing features are optional
- Remote contacts to shift phase angle or time setpoints are standard
- Transducer analog outputs are SCADA compatible
- Enhances system stability when applied to transmission and primary distribution reclosing schemes
- Detects a static phase angle across an open breaker in 0.5 second to assure a fast permissive for reclosure
- Simultaneously measures voltage magnitudes to ensure that they are within upper, lower and difference limits
- Includes dead line/dead bus closing features
- Remote command widens the phase angle setpoint to respond to system emergencies or to narrow the setpoint when the two systems are isolated to close the breaker very close to 0°
- Transducer analog outputs are SCADA compatible
- Panel-mounted G.E. IJS and SLJ or Westinghouse CVE replacement
- Accurate, independent phase, time and voltage functions
- Transducer and status outputs are standard features
- Modular construction allows cards to be removed while unit is installed
- Optional unit with voltage checking, dead line and dead bus closure capabilities can be installed at any time
- Does not require a separate power source
- Complete test and checkout from front panel
- 20 A output relay contacts open 0.9 A inductive at 125 V dc
- Panel-mounted G.E. IJS and SLJ or Westinghouse CVE replacement
- Accurate, independent phase, time and voltage functions
- Transducer and status outputs are standard features
- Modular construction allows cards to be removed while unit is installed
- Dead line/dead bus closure capability is standard
- Does not require a separate power source
- Complete test and checkout from front panel
- 20 A output relay contacts open 0.9 A inductive at 125 V dc
View All Products
Featured Solutions
M-2001D Digital Tapchanger Control for Transformers and Regulators
M-3311A Transformer Protection Relay
M-3425A Comprehensive Generator Relay
M-3520 Intertie Protection Relay
M-4172 Digital Motor Bus Transfer System For Low Voltage (LV) Switchgear Applications
M‑4272 Digital Motor Bus Transfer System
M-6200A Digital Voltage Regulator Control
M-6280A Digital Capacitor Bank Control
M-6283A Three Phase Digital Capacitor Bank Control
SmartBank Capacitor Bank Solutions
M-7651A D-PAC (Protection, Automation and Control System for Power Distribution Applications)
All Product Solutions
B-1953 6kV Surge Protection Assembly
B-2083 SmartBank Three Phase Junction Box
M-0001 Battery Transient Suppressor
M-0115A Parallel Balancing Module
M-0121 / M-0169A Auxiliary Current Transformer Units
M-0124 Surface-Mounting Adapter Kit
M-0127A/M-0170A Overcurrent Relay
M-0188A Syncrocloser® Check Relay
M-0359 Syncrocloser® Check Plus Relay
M-0362 Voltage Isolation Transformer
M-0388 Syncrocloser® Check Relay
M-0390 Syncrocloser® Check Plus Relay
M-2001C Digital Tapchanger Control
M-2001D Digital Tapchanger Control for Transformers and Regulators
M-2025B Current Loop Interface Module
M-2025D Current Loop Interface Module
M‑2026 AC‑DC Control Power Backup Supply
M‑2027 Control Power Backup Supply–AC Only
M-2032B Battery Charger/Power Supply
M-2035 Analog to Digital Interface Module
M-2050 Surface Mount Adapter Kit
M-2051/M-2052 Flush Mount Connection Harness Kit
M-2053 Flush Mounting Adapter Panel Bracket
M-2054 Surface Mount Adapter Kit
M‑2406 Recloser Control Adapter Chassis
M-2501B Autodaptive® Capacitor Control
M-2979 Recloser Control Cabinet
M-3310 Transformer Protection System
M-3311 Transformer Protection System
M-3311A Transformer Protection Relay
M-3420 Generator Protection System
M-3425A Comprehensive Generator Relay
M-3430 Generator Protection System
M-3520 Intertie Protection Relay
M-4172 Digital Motor Bus Transfer System For Low Voltage (LV) Switchgear Applications
M‑4272 Digital Motor Bus Transfer System
M-5329 Three-Phase LTC Backup Control
M-5625 Syncrocloser® Digital Synchronizing System
M-6200A Digital Voltage Regulator Control
M-6280A Digital Capacitor Bank Control
M-6283A Three Phase Digital Capacitor Bank Control
M-7651A D-PAC (Protection, Automation and Control System for Power Distribution Applications)